ansys_shell181_integ_method

Sets the integration method used for Ansys SHELL181. reduced - uses uniform reduced integration. full - uses full integration. Default is full

Default: full

creo_ansys_all_results_visible

Defines if advanced result types, like various strains, are visible by default

Default: no

creo_ansys_contact_gap_behavior

Warn about gaps or overlaps at contacts before solving

Default: (No Value)

creo_ansys_large_deflection

Always assume large deflection in the solver calculations. Added in Creo 8

Default: off

creo_ansys_n-r_method

Allow the best method to be selected automatically

Default: (No Value)

creo_ansys_normal_modes

Specify the number of required natural frequencies for the modal solution

Default: 6

creo_ansys_solver_cores

Set the number of processor cores to be used by Creo Ansys solver. Currently supports 1-4 cores

Default: 2

creo_ansys_solver_type

Allow the most appropriate solver to be automatically selected for your model

Default: (No Value)

creo_ansys_use_inertia_relief

Choose whether to replace the constraints with Inertia Relief to allow solution for unconstrained models. Added in Creo 9

Default: (No Value)

custom_rainbow

Used to specify fringe colors in Pro/FEM-POST results. Specify blue, black, cyan, magenta, green, yellow, red, and white. Enter colors as a dash-delimited string (lowest to highest value). The default is blue-cyan-green-yellow-red-magenta-white

Default: (No Value)

enclosure_volume_transparency

Controls the enclosure volume transparency in shaded model display. You can change the value in the range between 0.0 and 1.0. The bigger the value, the more transparent the enclosure volume. The default value is 0.92. Controls transparency of enclosure volumes

Default: 0.92

fem_allow_named_mesh_files

Yes - The user will be prompted to select a file to retrieve the mesh from, or enter a file name to save the mesh to. No - The user will not be prompted to select or enter a mesh file name

Default: no

fem_ansys_annotations

Toggle transfer of load set names to ANSYS

Default: no

fem_ansys_grouping

Toggle transfer of groups/layers to ANSYS

Default: no

fem_asp_ratio

The value that FEM created elements of aspect ratio are compared against

Default: 7

fem_default_solver

Specify the default solver to be used in FEM mode

Default: (No Value)

fem_dist_index

The value that FEM created elements of distortion indices are compared against

Default: 0.4

fem_edge_angle

Sets the minimum acceptable default angle between adjacent element edges. Enter value between 0 and 90

Default: 30

fem_hierarchical_mesh

Yes - Store and retrieve automatically the FEM mesh in the mesh file upon its creation and on entering Creo Simulate, respectively. This option triggers Hierarchical Mesh mode. No (default) - Do not store or retrieve the FEM Mesh automatically

Default: no

fem_inertia_relief

Enable inertia relief in FEM mode. Creo Simulate will output PARAM,INREL,-2 to a Nastran deck file or XYZ to ANSYS PREP7 file

Default: no

fem_keep_solver_files

Yes - All Solver files will be retained after running the analysis. No - All Solver files will be deleted after running the analysis

Default: no

fem_mesh_auto_retrieve

Yes - The FEM mesh will automatically be retrieved from the current working directory on entering Creo Simulate. No - The mesh will not be retrieved automatically. The default is NO

Default: no

fem_mesh_auto_save

Yes - The FEM mesh will be saved in the current working directory after it is created. No - The mesh will not be saved automatically after it is created. The default value is No

Default: no

fem_mesh_operations

Yes - The menu item Operations appears in the FEM MESH menu, providing access to functionalities to manipulate the finite element mesh. No - the menu FEM MESH will not have the item Operations

Default: no

fem_mid_ratio

The value that FEM created elements of mid ratios are compared against

Default: 0.1

fem_neutral_version

Specify the version number of neutral file

Default: 3

fem_preserve_mesh

Yes - Issue a warning whenever the current operation invalidates the existing FEM mesh. No (default) - Erase the mesh without notification when it becomes incompatible with the model

Default: no

fem_shell_elem_type

Sets the default shell element type in FEM mode

Default: quad

fem_skew_angle

Sets the maximum acceptable default skew angle value, measured in degrees. Enter a value between 0 and 90

Default: 45

fem_solver_time_limit

Interrupt the Nastran solver after the specified time limit in minutes using the TIME executive card. A negative number directs the solver to use its own default. The default value of this option is -1

Default: -1

fem_taper

Sets the minimum acceptable default taper value. Enter a value between 0 and 1

Default: 0.5

fem_warp_angle

Sets the maximum acceptable default warp angle value, measured in degrees. Enter a value between 0 and 90

Default: 10

fem_which_ansys_solver

Specifies the ANSYS equation solver type to be used. Supported solver types: FRONTAL, ITERATIVE (JCG), POWERSOLVER (PCG), ICCG, AUTO, and SPARSE

Default: (No Value)

fem_y_dir_compress

Specifies the Y-direction based on compressed and uncompressed geometry. The default value is uncompressed

Default: no

pro_ansys_path

Specify the path to ANSYS executable. Sets path to ANSYS executable

Default: (No Value)

pro_genesis_path

Specifies the path to the Genesis executable. Sets path to Genesis executable

Default: (No Value)

pro_nastran_path

Specify the path to MSC/NASTRAN executable. Sets path to MSC/NASTRAN executable

Default: (No Value)

pro_nei_nastran_path

Specifies the path to the NEi Nastran executable. Sets path to NEi Nastran executable

Default: (No Value)

pro_solver_name

Specifies the name of the user-defined solver to be included in the SOLVE menu. See also pro_solver_path

Default: (No Value)

pro_solver_path

Specifies the path to the user-defined solver whose name is defined in the SOLVE menu. See also pro_solver_name. Sets path to user-defined solver executable

Default: (No Value)

sim_additive_mass

Treats Mass Idealizations as additive if they are applied to the same entity and suppresses Mass precedence rules

Default: no

sim_agem_delete_mesh_points

Yes - Deletes the points inserted during an AutoGEM session when deleting mesh elements. No - Retains the points inserted during an AutoGEM session when deleting mesh elements

Default: yes

sim_agem_edge_by_crv_default

Sets the default value for the ratio of Edge Length / Radius of curvature

Default: 2

sim_agem_edge_crv

Sets the value for the target ratio of Edge Length / Radius of curvature for automatic creation of a global AutoGEM Control

Default: (No Value)

sim_agem_model_thickness

Set the value to the part thickness. This causes AutoGEM to perform more boundary refinement, and can be very useful for thinner parts

Default: -1

sim_auto_create_thinsolids

Create automatic thin solids during mesh

Default: no

sim_auto_map_max_angle

Sets the default maximum angle tolerance for auto-mapping of pressure load. The valid range is from 0 to 90 degrees

Default: 10

sim_auto_map_max_dist

Sets the default maximum distance tolerance (relative to model size) for auto-mapping of pressure load. The default value is 0.0012

Default: 0.0012

sim_auto_pairing_thickness

Set the value of characteristic thickness for auto-detection of shell pairs. Using this as a threshold value, auto-detection will find surface pairs with thickness smaller than this value

Default: (No Value)

sim_auto_regen_enabled

Yes - Regenerate model on entrance to Creo Simulate. No - Don't regenerate the model

Default: yes

sim_beamsection_path

Specifies the path where the Beam Sections will be stored. Sets path where Beam Sections are stored

Default: (No Value)

sim_bearing_allow_cone_sel

Allow cone selection for creation of bearing load

Default: no

sim_calculate_node_reaction

Enables node reaction calculations for point constraints within links. The default value is NO

Default: no

sim_check_jacobian_corners

No - Suppress Jacobian checks at corner nodes. ANSYS and Nastran checks parabolic elements Jacobian at the integration points only and FEM will fix too curved elements for the same criterion. Yes - Jacobian is checked both at integration points and corner nodes. FEM mode will fix too curved elements accordingly

Default: no

sim_contact_penetration

Specify the value of contact penetration depth in percentage (greater than 0.0 up to 100.0 with default as 5.0)

Default: 5

sim_contact_tolerance_factor

Modifies the convergence tolerance for contact. The specified factor will be multiplied by the default tolerance

Default: 1

sim_display_agem_controls

Toggle display of AutoGEM Controls

Default: (No Value)

sim_display_arrow_scale

Toggle automatic arrow scaling

Default: (No Value)

sim_display_arrow_tail_touching

Toggle display of Load arrows to have tails or heads touching

Default: (No Value)

sim_display_beam_releases

Toggle display of Beam Release icons

Default: (No Value)

sim_display_beam_sections

Toggle display of beam section icons

Default: (No Value)

sim_display_beams

Toggle display of beam icons

Default: (No Value)

sim_display_beams_mode

Specify the display mode of icons for Beams

Default: (No Value)

sim_display_contacts

Toggle display of contact icons

Default: (No Value)

sim_display_cracks

Toggle display of crack icons

Default: (No Value)

sim_display_fasteners

Toggle display of Fastener icons

Default: (No Value)

sim_display_fasteners_mode

Specify the display mode of icons for Fasteners

Default: (No Value)

sim_display_highlight_refs

Yes - Geometrical references are highlighed when selecting a load/constraint

Default: (No Value)

sim_display_in_spin

Toggle display of simulation objects in Dynamic Spin

Default: (No Value)

sim_display_internal_mesh_edges

Specifies whether internal edges of mesh elements should be displayed in the wireframe mode. The default is "No"

Default: no

sim_display_load_distribution

Toggle display of distributed load vectors over entire entity

Default: (No Value)

sim_display_load_icons

Toggle display of load icons

Default: (No Value)

sim_display_load_name

Yes - The load/constraint name appears in the label

Default: (No Value)

sim_display_load_value

Toggle display of Load values

Default: (No Value)

sim_display_loads_from_comps

Toggle display of loads and constraints defined on lower-level components of assembly

Default: (No Value)

sim_display_loads_mode

Specify the display mode of icons for Loads and Constraints

Default: (No Value)

sim_display_loads_zi

Toggle zoom-insensitive behavior of shaded icons for Loads and Constraints

Default: (No Value)

sim_display_masses

Toggle display of mass icons

Default: (No Value)

sim_display_masses_mode

Specify the display mode of icons for Masses

Default: (No Value)

sim_display_masses_zi

Toggle zoom-insensitive behavior of shaded icons for Masses

Default: (No Value)

sim_display_matl_assignments

Toggle display of Material Assignment icons

Default: (No Value)

sim_display_measures

Toggle display of Simulation Measure icons

Default: (No Value)

sim_display_mesh_and_model

Toggle display of Mesh together with Model

Default: (No Value)

sim_display_mesh_control_name

Yes - The Mesh/AutoGEM control name appears in the label

Default: (No Value)

sim_display_mesh_control_value

Yes - The Mesh/AutoGEM control value appears in the label

Default: (No Value)

sim_display_mesh_controls

Toggle display of Mesh Controls

Default: (No Value)

sim_display_mesh_entities

Toggle display of Mesh entities

Default: (No Value)

sim_display_mesh_mode

Specify the mode of mesh display in FEM preprocessor

Default: (No Value)

sim_display_mesh_quality

Specify the quality of mesh display in Creo Simulate

Default: (No Value)

sim_display_mesh_shells_thick

Toggle the display of shell thickness in Creo Simulate mesh. YES - Display shells with real thickness. NO - Display shells with zero thickness

Default: (No Value)

sim_display_mesh_shrink_elems

Control display of Mesh through a specified percentage of shrinking of its elements

Default: -1

sim_display_model_type

Toggle the display of the Simulation model setup in the lower left corner of Creo screen

Default: yes

sim_display_names

Toggle display of Simulation Object names

Default: (No Value)

sim_display_rigid_dof

Toggle display of Rigid Link DOF icons

Default: (No Value)

sim_display_shells

Toggle display of shell icons

Default: (No Value)

sim_display_shells_mode

Specify the display mode of icons for Shells

Default: (No Value)

sim_display_springs

Toggle display of spring icons

Default: (No Value)

sim_display_struct_constraints

Toggle display of structure constraint icons

Default: (No Value)

sim_display_struct_loads

Toggle display of structure load icons

Default: (No Value)

sim_display_therm_bcs

Toggle display of Thermal Boundary Condition icons

Default: (No Value)

sim_display_therm_loads

Toggle display of thermal load icons

Default: (No Value)

sim_display_weighted_dof

Toggle display of Weighted Link DOF icons

Default: (No Value)

sim_display_welds

Toggle display of Weld icons

Default: (No Value)

sim_expanded_diagnostics

Yes - Creo Simulate will perform an expanded set of diagnostic checks during meshing a model or running an analysis. These include checks for interferences in an assembly and for singular geometry. No - Creo Simulate will not perform expanded checks

Default: no

sim_extend_surf_max_angle

Controls the maximum angle between a surface to be extended during shell compression and its adjacent surfaces. If the angle is higher than specified, the adjacent surfaces is extended. The default is 30 degrees. The range is from 0 to 90 degrees

Default: 30

sim_fatigue_biaxiality_correct

Controls the use of biaxiality correction. The default value is YES

Default: yes

sim_fatigue_biaxiality_method

Controls which method is used to model biaxiality: SIMPLE calculates a simple biaxiality ratio only, STANDARD uses nCode method of assessment and AUTO performs the standard method, but may recalculate depending on the results of the assessment. The default value is AUTO

Default: auto

sim_fatigue_confidence_level

Specifies the percentage confidence in the predicted life result value. The default value is 90, and range is from 0.1 to 99.9

Default: 90

sim_fatigue_external_matdata

Controls the use of external material data. The default value is NO

Default: no

sim_fatigue_infinite_life_value

Specifies the value for the lives beyond cutoff. The default value is 1e20 and range is from 1e15 to 1e30

Default: 1E+20

sim_fatigue_max_safety_factor

Specifies the value for the maximum factor of safety. The default value is 5.0 and range is from 2.0 to 5e6

Default: 5

sim_fatigue_mean_stress

Controls the application of the mean stress correction. The default value is YES

Default: yes

sim_fatigue_mean_stress_method

Controls which method is used to model mean stress: the Morrow Correction or the Smith-Watson-Topper Approach. The default value is MORROW

Default: morrow

sim_fatigue_safety_margin

Specifies a factor used to determine the Life Confidence quantity. The default value is 3 and range is from 1.1 to 100

Default: 3

sim_fatigue_user_directory

Specifies the directory for user files (for example, external material files). The default value is the current directory. Sets directory for simulation user files

Default: (No Value)

sim_fatigue_write_surf_stress

Controls writing of surface stresses to a neutral file. The default value is NO

Default: no

sim_fem_mapped_mesh

Default number of sub-divisions for mapped meshing in FEM mode. Default value is 10 and range is from 1 to 99

Default: 10

sim_fem_nastran_use_pshell

Yes - use PSHELL cards, No - use PCOMP cards for laminate composite shells in NASTRAN output file

Default: no

sim_html_report_prefs_file

Specifies the path to the Simulation post processor HTML report preferences file. Sets path to Simulation HTML report preferences file

Default: (No Value)

sim_hyperelastic_material_fit

Sets the default method for calculating coefficients for hyperelastic materials. If set to "normalized", normalized stresses will be used. If set to "non-normalized", non-normalized stresses will be used

Default: normalized

sim_icon_distribution_density

Determines how many icons are drawn for a distribution. 1 is fewer, 10 is the highest

Default: -1

sim_ignore_unpaired

Control whether unpaired surfaces are ignored when meshing the model

Default: no

sim_invoke_diagnostics_on_run

Sets the default for the display of diagnostics during the run of an analysis in Creo Simulate Native mode. If set to prompt, the user is prompted to run diagnostics every time he/she starts a run

Default: prompt

sim_live_result_quality

Set the default value of accuracy for live simulation. The value varies from 0.05 to 1.0, and can be changed by multiples of 0.05

Default: 0.25

sim_load_mech_mesh

No - The user is prompted to load the existing Creo Simulate mesh file from the current working directory. Yes - The mesh file, if exists, is loaded automatically and the mesh is displayed

Default: no

sim_loadpreview

Sets the type of load preview: vectors, fringe or mesh

Default: fringe

sim_massnorm_modes

Mass normalize modes. If set to no, the modes are normalized to a maximum displacement of 1. The default is no

Default: no

sim_mat_poissons_notation

Specifies the convention used for defining Poisson's ratio for anisotropic materials as being either Tsai (Column-normalized) or Jones (Row-normalized). This option affects only the labels for Poisson's ratio on the Material data form

Default: tsai

sim_max_contact_iterations

Specify the maximum number of iterations for contact analysis. The default is 200

Default: 200

sim_max_memory_usage

Specifies the maximum amount of memory in megabytes to be allocated during FEM meshing. If this option is not set, or set to zero, the mesher can use all available memory

Default: (No Value)

sim_modal_disp_superposition

Specify whether modal displacement superposition should be used in dynamic analyses

Default: yes

sim_modal_stress_superposition

If set to yes, use the modal stress superposition method to compute the stress results. If set to no, use the superconvergent stress recovery method

Default: yes

sim_native_mapped_mesh

Default number of sub-divisions for mapped meshing in Native mode. Default value is 3 and range is from 1 to 99

Default: 3

sim_newton_debugprint

Output newton and snapthrough debug info to pas file

Default: no

sim_newton_tolerance_factor

Modifies the convergence tolerance for newton loop. The specified factor will be multiplied by the default tolerance

Default: 1

sim_nl_ldc

Output load deflection curve to ldc file

Default: yes

sim_output_ids_for_layers

Outputs FEM mesh element IDs on each layer into XML file

Default: no

sim_override_axis_selection

Override the default axis selection for symmetry constraint

Default: no

sim_perturbation_solvers

Use perturbation solvers in the calculation of local sensitivity. The default is yes

Default: yes

sim_pp_background_color

Specifies the background color of the work area for the results display. The default value is PROE

Default: proe

sim_pp_display_beam_thickness

Sets the thickness for beams and 2D-shells display in Post Processor. Numerical values specify the thickness in pixels

Default: 5

sim_pp_display_spin_center

Sets the default for the behavior of mouse spinning the model in results

Default: yes

sim_pp_legacy_selection

Enables legacy selection of geometrical entities from Creo Simulate results postprocessor on Creo Simulate geometry

Default: no

sim_pp_legend_continuous

Determines if the legend will be continuous tone (YES) or discrete colors (NO)

Default: no

sim_pp_legend_levels

The default number of legend levels (from 1 to 16; the default is 9)

Default: 9

sim_pp_legend_show

If set to NO, the legend is not displayed in newly created results windows by default

Default: yes

sim_pp_legend_show_min_max

If set to NO, the gray minimum and maximum values are not displayed by default in the legend

Default: yes

sim_pp_legend_spectrum

This string sets the default color legend used in the definition of a results window. This file will be looked up in the sim_pp_template_dir location, or, if this is not specified, in the current working directory

Default: (No Value)

sim_pp_linked_results

Set this option to Yes to link the vaulted Simulate results to the model that is checked in, for this session. The default value of this option is Yes

Default: yes

sim_pp_path_absolute

Choose Absolute (Yes) or Relative (No) path to "rwd" file

Default: no

sim_pp_query_location

Sets the default value for the display of the WCS location in dynamic query in results

Default: yes

sim_pp_show_cap_cut_outline

Enables to hide the model outline in capping/cutting surface display

Default: yes

sim_pp_struct_avg_res

Yes - Averages results in Simulate Results. Applicable only for Creo Simulate Structure Mode Analysis types

Default: no

sim_pp_template_dir

Sets the default directory for results template files. Sets directory for results template files

Default: (No Value)

sim_pp_vector_plot_arrow_2d

To draw 2D arrows instead of 3D arrows while post-processing vector results. It is useful when system memory is not sufficient to display3D vector arrows

Default: no

sim_pp_vrml_export_format

Flags to denote VRML1.0 or VRML2.0 (default) output

Default: vrml2.0

sim_pp_vrml_feature_edges

Flag to enable the inclusion of feature edges in the VRML file. The default value is NO

Default: no

sim_prop_range_factor

A factor to compare Simulate properties and warn about large variations

Default: 1000

sim_reentrant_geom_angle

Sets the default value for reentrant geometry detection in both Isolation for Exclusion AutoGEM Control and expanded diagnostics checks. The valid range is from 0 to 180 degrees. The default is 120 degrees

Default: 120

sim_remove_unopposed

Yes - The system ignores unopposed surfaces when meshing the model; the system also deselects the UseUnopposed option. No - the system uses the unopposed surfaces in the shell model

Default: no

sim_results_on_first_pass

Forces results post-processing after the first pass of an SPA analysis

Default: no

sim_run_out_dir

Specify the directory for Creo Simulate run output storage. By default, the current directory is used. Sets directory for Creo Simulate run output storage

Default: (No Value)

sim_run_tmp_dir

Specify the directory for Creo Simulate run temporary storage. By default, the current directory is used. Sets directory for Creo Simulate run temporary storage

Default: (No Value)

sim_sif_measure_size_factor

Controls the size of the elements that touch the tip of the crack, relative to the size of the crack

Default: 0.1

sim_smooth_aspect_ratio

Sets the element aspect ratio criterion for the mesh smoothing process

Default: 7

sim_smooth_edge_angle

Sets the element edge angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process

Default: 30

sim_smooth_skew

Sets the element skew angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process

Default: 45

sim_smooth_taper

Sets the element taper criterion (Quad elements only) for the mesh smoothing process

Default: 0.5

sim_smooth_warp_angle

Sets the element warp angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process

Default: 10

sim_snap_tolerance_factor

Modifies the start tolerance for snapthrough. The specified factor will be multiplied by the default tolerance

Default: 1

sim_solver_memory_allocation

Specifies the amount of memory in megabytes reserved for solving equations and for storing element data created by the iterative solver. The default value is 512

Default: 512

sim_spotweld_split_mesh

If set to YES (default), the elements that touch the end of the spot weld are created in a circle the same diameter as the weld (AutoGEM only)

Default: yes

sim_struct_interface_default

Sets the default for the interfaces created between the geometry in a structural model for meshing and running analysis

Default: bonded

sim_sturm_sequence

Run the Sturm sequence test for a modal analysis. By default, the solver automatically decides when to perform the Sturm sequence test

Default: default

sim_supercon_recovery

Sets on or off the superconvergent stress recovery algorithm

Default: yes

sim_therm_interface_default

Sets the default for the interfaces created between the geometry in a thermal model for meshing and running analysis

Default: bonded

sim_thinsolid_char_thickness

Controls the characteristic thickness for automatic thin solids

Default: 5

sim_use_layers

Allows layers to become groups for Creo Simulate Independent mode

Default: no

sim_wf5_fastener_fix_separation

Sets the value of Fix Separation for fasteners created in Wildfire 5.0 or earlier with Fix Separation set to Auto

Default: default

sim_wf5_fastener_frictionless

Sets the value of Frictionless Interface for Fasteners created in Wildfire 5.0 or earlier

Default: default

simlive_contact_detect_inactive

Define how automatic contact creation will be handled for inactive studies. Only applicable if contacts are present in the model. Added in Creo 9

Default: always

simlive_default_simulation

Set the default Live Simulation type

Default: structural

simlive_reference_scope

Define the behavior upon selection of simulation entities references

Default: prompt

simulation_fem_mode

Yes - Activate FEM mode of Creo Simulate. No (default) - Activate Native mode of Creo Simulate

Default: no

simulation_mode

Specify Creo Simulate mode - Structure (default) or Thermal. This option is used only if the information about Creo Simulate mode is not yet stored with the model

Default: structure

simulation_probes_auto_hide

Define whether Probes of other simulations studies will be automatically hidden upon Study activation

Default: yes

simulation_process_auto_advance

If set to yes the Process Guide will advance to the next set automatically upon completion of the current step

Default: no

simulation_process_prompt

If set to yes, the Process Guide will be launched automatically upon entry into Creo Simulate, if template files are present

Default: no

simulation_process_template_dir

Specifies the default location of the Process Guide template files. Sets directory for Process Guide template files

Default: (No Value)

std_nastran_template

Sets the file path of a NASTRAN deck template. Use full path to avoid problems. Sets file path of NASTRAN deck template

Default: (No Value)
Back to Categories
Back to Categories